Panamax M5300-PM
Improves Picture and Sound Quality, Monitors Incoming Line Voltage, and Reduces Cross-Contamination Between Components.
Improves Picture and Sound Quality
Level 4 Power Cleaning and Filtration eliminates common symptoms of contaminated power (including loss of detail, pops, hisses, hums and visual artifacts) and allows your A/V equipment to perform up to its full capability.
Monitors Incoming Line Voltage and Provides a Visual Indication of Power Level
Panamax™ patent pending AVM circuitry continuously monitors the incoming power as displayed on the digital voltmeter. In case of an undervoltage or an overvoltage, a flashing red lightning bolt will be displayed in the voltmeter, and power to the connected equipment is automatically turned off if either of these conditions is detected. When voltage returns to a safe level, power to the equipment is automatically reconnected.
Reduces Cross-Contamination Between Components
The M5300-PM is designed to provide noise isolation between 5 isolated outlet banks (including 1 bank with 2 high current outlets) so that any noise created by an A/V component cannot contaminate the power going to equipment plugged into another outlet bank.
- General:
- Line Voltage: 120 (Volts)
- BlueBOLT Enabled: No
- Power Factor Technology: No
- Number of Outlets: 11
- Number of Isolated Banks: 5
- Outlet Descriptions :
1 (always on, linearly filtered outlet, front panel)4 (always on, linearly filtered outlets, rear panel)
- 4 (switchable, linearly filtered outlets, rear panel)
- 2 (switchable high current outlets, rear panel)
Other::
- Rack Mountable Yes
- Rack Ears Included Yes
- Front Panel Meter: 1 voltmeter, 1 Ammeter
- Control On/Off control of switched outlets through front panel power button or rear panel DC trigger.
- Voltage Regulation: No
- USB Charging1 front panel USB charger
- Low Voltage Trigger12 V, In/Out
AC Power Cord10 ft. detachable
- Dimensions17″ W x 12.75″ D x 3.5″ H, (4.1″ Including feet)
- Weight 12.8 lbs
AC Protection:
- AC Protection TechnologyProtect or Disconnect
Automatic Voltage Monitoring
L-N, L-G, N-G Protection Modes
Thermal Fusing
- Automatic Voltage Shutoff: Yes
- Under-Voltage Shutoff90 VAC ± 2 VAC
- Over-Voltage Shutoff142 VAC ± 8 VAC
- Maximum Current Rating: 15 (Amps)
- Initial Clamping Level: 200V Peak
Filtration
- Filtration Technology: LiFT
- Filtration RatingBank 1: Up to -86 db (100 KHz _ 2 MHz)Bank 2: Up to -91 db (100 KHz _ 2 MHz)
- Bank 3: Up to -81 db (100 KHz _ 2 MHz)
- Bank 4: Up to -100 db (100 KHz _ 2 MHz)
- Bank 5, High Current Outlets: Up to -81 db (100 KHz _ 2 MHz)
- Signal Line Protection
- Signal Line Protection2 LAN, 1 Tel, 3 Cable/Satellite
- Shipping Info
- Length20.3 (Inches)
- Width: 10.3 (Inches)
- Height: 24 (Inches)
- Weight: 19.55 (Lbs)
Other Specifications
- Voltage Protection Rating (UL 1449 3rd Edition, 3,000A)500V
- Single Pulse Energy Dissipation2125 Joules
- Peak Impulse Current72,000 Amps
- LAN – Wires Protected8-Wires
- LAN – Compatibility10/100bT
- LAN – Clamping Level60V ± 5V
- Coax – ShieldedYes
- Coax – Insertion Loss< 0.5 dB
- Coax – HD 1080 i/p ReadyYes
- Coax – Frequency Range0 MHz – 2.2 GHz
- Coax – ConnectionsFemale ñFî, Gold Plated
Coax – Clamping Level75V
- Coax – Bidirectional: Yes